For DCBmeasurements: when a negative polarity is present at the r
indicated value is preceded by a "B" sign.
When the measured value is higher than the selected range limit, th
"OL". Select a higher range.
7.2 Current measurements
Do not measure current in circuits with voltages > 250V
Current measurements: IAmA jack max. 300mA; for measurement
10A jack. When measuring currents above 5A, max. 15s continuous
by a 10 minutes break between 2 measurements.
Always be careful when working with voltages above 60Vdc or 30Va
fingers behind the probe barriers at all times during measurement.
For measurements up to 300mA: connect the red test lead to the "I
black lead to the "COM" jack.
For measurements up to 10A: connect the red test lead to the "10A
lead to the "COM" jack.
Set the function selector to A
Set the function selector to mA
When the range is unknown, always select the highest possible range a
appropriate range.
Connect the test probes in series with the circuit.
Read the measured value from the display.
When desired, select a range manually with the RANGE button.
Notes:
For DCBcurrent measurements, when a negative polarity is present
the indicated value is preceded by a "B" sign.
The IAmABrange is protected against overBcurrent with a F300mA 2
the 10ABrange is protected against overBcurrent with a F10A 250V f
When measuring above 5A, max. 15s continuous measurement foll
break between 2 measurements.
When the measured value is higher than the selected range limit, th
"OL". Select a higher range.
7.3 Resistance measurements
Do not perform resistance measurements on live circuits.
Make sure all capacitors in the circuit are discharged.
Connect the red test lead to the "VJF" jack and the black lead to the "
Set the rotary switch to the K range.
Connect the test probes to the circuit/component under test.
The measured value appears on the display.
When desired, select a range manually with the RANGE button.
Notes:
Never perform resistance measurements on a live circuit and make s
o
completely discharged.
For resistance measurements above 3.26ML the meter needs a few s
o
readBout.
Should the measured resistance exceed the selected range or in case
o
display will show "OL".
7.4 Continuity & diode test
Do not perform continuity or diode measurements on live cir
Make sure all capacitors in the circuit are discharged.
Connect the black test lead to the COM jack and the red test lead to th
Set the rotary selector to
25.02.2011
DVM68
for measurements up to 10A on the 10
or IA
for measurements up to 30
/
.
8
Rev. 01
e red test lead, the
, the display will show
ents up to 10A use the
ous measurement followed
0Vac rms. Keep your
IAmA" jack and the
0A" jack and the black
10A jack.
00mA on the IAmA jack.
e and lower to the
nt at the red test lead,
250V fuse (Ø5x20mm),
V fuse (Ø6.3x30mm).
followed by a 10 minutes
, the display will show
e "COM" jack.
e sure all capacitors are
w seconds to stabilize the
se of an open circuit, the
circuits.
the VJF jack.