6. Operation
Principle of operation
The dehumidifi er monitors the relative humidity
of the inlet air. The humidity condenses on the
cooling elements and is directed into the water
collector. The dry air – warmed slightly at the
condenser – is returned to the room. A refrigerant
compressor is needed for the dehumidifi er's ope-
ration.
Note:
The room temperature must lie in the range
from 5 to 35 °C and the room humidity must
lie in the range from 40 to 95 % RH. The de-
humidifier does not work outside this range.
To achieve an optimum circulation of air you
should set up the equipment in the middle of
the room if at all possible.
Avoid opening windows and doors, avoid en-
tering and leaving the room frequently, etc.
The equipment must not be used in environ-
ments containing lots of dust or chlorine.
The dehumidifier's performance depends
on the room's conditions, temperature and
humidity.
If the condensate collector is not fitted cor-
rectly, the equipment will not work.
To prevent high starting currents, the equip-
ment has a restart inhibit function which does
not allow the compressor to be switched on
again until after a waiting period of 3 minutes.
The LEDs shine when the function has been set
(Item 11 – 16).
1. If the device is supplied with mains voltage,
the "Power" LED shines (Fig. 2 / Item 12).
2. To switch on, press the On/Off switch (Fig. 2 /
Item 21).
3. Fan speed
To choose between a high and a low fan
speed, press the "Fan speed" switch (Fig. 2 /
Item 24).
4. Desired humidity
Press the switch „Humidity setting" (Fig. 2 /
Item 22) to adjust the set-point humidity to
between 40% and 80% in steps of 5%. If the
prevailing humidity at the integrated sensor
falls below the desired humidity setting by ap-
Anl_LE_10_SPK7.indb 14
Anl_LE_10_SPK7.indb 14
7. Emptying the condensate
collector
GB
prox. 2%, the compressor will stop, followed a
little later by the fan. If the prevailing humidity
at the integrated sensor exceeds the desired
humidity setting by approx. 2%, both the fan
and the compressor (3 minute restart inhibit
function) will start up again.
5. Timer
With the equipment ON, press the switch for
„Timer setting" (Fig. 2 / Item 23) to set the
desired operating time (1 - 24 h) in steps of
1h. If the timer is not ON, the equipment will
run continuously.
6. To switch off , press the On/Off switch (Fig. 2 /
Item 21).
Note:
The device switches off automatically when
the condensate collector (Fig. 1 / Item 7) is
full. The „Condensate collector full" LED will
light up and a warning signal will sound for a
few seconds.
If the condensate collector (Fig. 1 / Item 7) is
not refitted correctly after it has been emp-
tied, the "Condensate collector full" LED will
continue to shine.
Never remove the "Float" (Fig. 3 / Item A) from
the condensate collector, otherwise the auto-
matic switch-off function will no longer work.
If the condensate collector is dirty, you can
clean it with warm water.
1. Remove the condensate collector (Fig. 1 /
Item 7) by pulling it out carefully and then em-
pty it.
2. Slide the collector back into the device after
you have emptied it.