UHI-SBG-0 Series
5.4

Wire Preparation

Supply the UHI-SBG-0 with power by using a power cord that complies with the Nec 400-4
CEC rule 4-010 and is marked with INDOOR, W or W-A. For 24 V cameras, use the recom-
mended maximum cable length chart for selecting the proper wire size.
Wire Size mm
0.5
1
1.5
2.5
4
Table 5.1 Maximum cable lengths for 24 V camera housings
Preparing the Power Supply
Cut the power cord on 120 VAC and 230 VAC camera models; leave enough cable to allow a
connection to the terminal block. Strip no less than 6 mm (0.25 in.) and no more than 8 mm
(0.31 in.) of insulation away from the wire. Do not nick the wires.
Preparing the Terminal Block
Wire sizes larger than 2.5 mm
The terminal block accepts wires ranging from 0.5 to 2.5 mm
larger wire sizes, splice to a smaller size wire at the terminal block end. The splice may need
to be enclosed in a junction box if it does not pass through the fittings.
12 V - 230 V AC/DC L
Fig. 5.6 Terminal Wiring
WARNING! External interconnecting cables are to be installed in accordance to NEC, ANSI/
NFPA70 (for US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN
application) and in accordance to local country codes for all other countries.
!
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated
Fuses are required as part of the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be incorporated.
Bosch Security Systems, Inc.
Wire Size AWG
2
20
18
16
14
12
2
(14 AWG) require a splice to accommodate the terminal block.
WIRING DIAGRAM
N
GND
(not used) X
Installation Manual
Housing Distance
27 m (90 ft)
42 m (140 ft)
67 m (220 ft)
108 m (355 ft)
172 m (565 ft)
2
(20 to 14 AWG). When using
Camera
.............
September 15, 2006 | F01U032279_01
Installing the Housing | en
11