5.5.1
Cower supply control unit
Use the wiring diagram corresponding to your product.
Verify that the product is connected to mains by means of a perma-
nently installed cable, for example NYM-J 3 x 1.5 mm².
Verify that the power supply to the control unit is separately fused (16 A
maximum).
1. In the case of OM 5 and OM 5+1, route the mains cable through the
cable gland at the left into the control unit.
2. In the case of OM 1, route the mains cable through the cable gland at
the right into the control unit.
3. Connect the phase to terminal L1 and the neutral conductor to terminal
N.
Fig. 6: Electrical connection OM 5
Mounting
1. Supply voltage
2. Any external equipment
3. Green
4. Brown
5. White
6. Probe 1
7. Probe 2
8. Probe 5
F1 mains fuse
OM 5 / OM 5+1 / OM 1
EN
23