2.2
Intended use
This product is intended to detect water and to signal accumulations of oil
during monitoring of:
•
Collection facilities under storage tanks, burners or motors
•
Tanks with collection facilities which are not visible
•
Collection facilities below devices consuming oil
•
Manholes, pipe and cable ducts
•
Pump and control stations where oil can accumulate due to leaks or back-
flow
The product is suitable for liquids to which the polyamide (PA) hot melt is suf-
ficiently resistant, such as:
•
Diesel fuel (DIN EN 590) and low-viscosity oils with flash points of > 55 °C
at atmospheric pressure and at temperatures of -10 °C to +60 °C in dry
rooms.
•
Fuel oil EL, L or M
•
Unused and used motor oils (for example, SAE 15W-40), gearbox oils and
hydraulic oils, transformer oils, vegetable oils
•
AdBlue® (urea solution 32.5 %) as per DIN 70070/ISO 22241
•
Water, grey water
The owner or operator must ensure that the components and the overall sys-
tem meet all directives and regulations applicable at the installation site, for
example, the directives pertaining to water and waterways.
Leak detection system class III as per DIN EN 13160-1 and EN 13160-4 as
liquid sensor system in leak or interstitial spaces, as safety device as per
worksheet DWA-A 791 or leak detection system as per worksheet
DWA-A 779.
Any use other than the application explicitly permitted in these operating
instructions is not permitted and causes hazards.
Information on safety
OM 5 / OM 5+1 / OM 1
EN
4