Testing chemical protective suit (type 1b)

Visual inspection
Inspect all components. Check in particular for possible
damage (e.g. deformation, adhesion, contamination or
cracks). Replace faulty or damaged parts immediately.
Preparation of test
1. Seal the connections for protective suits with ventilation unit.
2. For protective suits with face cuffs:
a. Blow up the test fan moderately and close with a
hose clip.
b. Moisten the test fan with water and insert through the
open fastener system into the hood on the protective
suit.
c. Continue to blow the test fan until the face cuff is in
position all-round.
d. Close the test fan with a hose clip.
3. For protective suits with integrated full face mask:
a. Remove the protective cap from the connector.
b. Seal exhalation valve and inhalation valve with the test
accessories.
4. Close the fastener system.
5. Spread out the chemical protective suit back-down on a
clean and even surface.
6. Unfasten the protective cap from the suit valve and remove
the valve disc.
7. Fit the double test cap onto the suit valve.
8. Connec t the grey hose to a connector of the double test
cap and connect to the test unit with the mouth adapter.
9. Connect the black hose to the second connector of the
double test cap.
10. Make sure that both valves are closed at the black hose.
11. Connec t the black hose to the medium-pressure outlet of
the test unit.
12. Connect test unit to medium pressure.
Check the seal on the chemical protective suit
1. Open the exhaust valve on the black hose and fill the
chemical protective suit until the test unit shows 17.5 mbar.
Close exhaust valve.
2. Set a settling time of 10 minutes and start the stopwatch.
During this time, keep the pressure at approx. 17 mbar to
enable a pressure and temperature compensation.
If necessary, regulate the air with the applicable control
lever (+ or -).
3. Pull right control lever to reduce the pressure to 16.5 mbar.
4. Start test time of 6 minutes on the timer.
5. Read off the pressure at the end of the test time.
The pressure drop must not exceed 3 mbar.
26
Testing suit valve
1. Disconnect the black hose.
2. Disconnect the double test cap from the suit valve. Pull the
grey hose from the double test cap. Attach the mouth
adapter to the test unit with the hose.
3. Moisten valve disc with plain water and attach.
4. Attach the test cap with the grey hose to the suit valve.
5. Press left control lever to generate a positive pressure of
approx. +12 mbar.
6. Pull left control lever to generate a positive pressure of
approx. +10 mbar.
7. Start test time of 1 minute on the timer.
8. Read off the pressure at the end of the test time.
The pressure difference must not exceed ±1 mbar.
9. Disassemble test setup.
10. Fit the protective cap onto the suit valve.