Emergency Stop Switch; Starting The Machine; Overload - Husqvarna HTC 270 EG Manuel De L'opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

HTC 270 EG
4.8.2

Emergency stop switch

The emergency stop switch, (EM-Stop) must only be used in an emergency.
When the switch is pressed, all electrically-powered equipment on the machine are
turned off.
Note!
Do not use the emergency stop switch to stop the machine other than in
emergencies, as it can damage the machine.
Note!
As long as the emergency stop switch (EM-Stop) is pressed, the machine
cannot be started. Reset by turning the switch 45° so that it pops out again. The
machine can then be restarted.
4.8.3

Starting the machine

For a description of the control panel, see section Description of controls – Control
panel, page 11.
1. Connect the electricity supply by plugging in the plug.
2. Make sure the emergency stop switch is reset.
3. Turn the Power knob to "I" to activate the electronics.
4. Set the speed for the grinding discs using the Speed knob.
5. Turn the Grinding knob to "FWD".
6. The machine has now started.
4.8.4

Overload

If the machine is using too much power, the Overload indicator on the control panel
goes off. The machine switches off automatically after a while if this is ignored. Reduce
the speed of the grinding discs to see if the Overload indicator goes out. If this does not
help, follow the procedure for troubleshooting, see chapter Faultfinding, page 34.
2.0
Usage
23

Publicité

Table des Matières
loading

Table des Matières