Lenze L-force 9400 Instructions De Montage page 64

Masquer les pouces Voir aussi pour L-force 9400:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Overview
Pos.
Description
MXI1
Module receptacle for extension 1, e.g. communication
MXI2
Module receptacle for extension 2, e.g. communication
MMI
Module receptacle for memory modules
MSI
Module receptacle for safety equipment
X1
System bus (CAN), under the cover
X2
24-V supply / Statebus
X3
Analog inputs / analog outputs
X4
Digital outputs
X5
Digital inputs
X6
Diagnostics (with diagnostic adapter or keypad)
X7
Resolver
X8
Encoder
Lower cap
Nameplate, retractable
Upper cap
EMC wire clamp
X100
Mains / DC-bus voltage
X105
Motor / external brake resistor
X106
Motor temperature monitoring (position depends on the device size)
X107
Control of motor holding brake
EMC shield clamp
Holes for transport and assembly guides
Shield connection/strain relief (device sizes: 8S, 8 and 9)
Barrier between mains input and other power terminals (device sizes: 8S, 8
and 9)
Switch for operation in IT systems
The LED display enables fast indication of several operating states.
LED
Labelling
CAN-RUN
CAN-ERR
DRIVE READY
DRIVE ERROR
24 V
USER
SSP94LED01
Pos.
Symbol
© 2007 Lenze Drive Systems GmbH, Hans-Lenze-Straße 1, D-31855 Aerzen
No part of this documentation may be reproduced or made accessible to third parties without written consent by Lenze Drive
Systems GmbH.
All information given in this documentation has been selected carefully and complies with the hardware and software described.
Nevertheless, discrepancies cannot be ruled out. We do not take any responsibility or liability for any damage that may occur.
Necessary corrections will be included in subsequent editions.
64
Colour
Description
green
CAN bus o.k.
red
CAN bus error
green
Standard device is ready for operation
red
Error in the standard device or due to the application
green
24-V supply voltage o.k.
yellow
Message parameterised by the application
Description
Long discharge time: All power terminals carry hazardous voltages for at
least 20 minutes after mains disconnection!
High discharge current: Fixed installation and PE connection to EN 61800-5-1
required!
Electrostatic sensitive devices: Before working on the device, the personnel
must remove any electrostatic charges using suitable measures!
Design
HighLine
2/2
4
8
Optional
Optional
2
4
Inoperable when "StateLine" design is
used
EDK94SH366 DE/EN/FR/ES/IT 3.1
StateLine
1/0
1
4
2
4

Publicité

Table des Matières
loading