Lenze L-force 9400 Instructions De Montage page 122

Masquer les pouces Voir aussi pour L-force 9400:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6
Wiring the device modules
Safety modules
Displays
Pos.
MS
(Module State)
EN
(Enable)
ME
(Module Error)
AS
(Acknowledge Stop)
BE
(Bus Error)
DE
(Drive Error)
Blinking: on/off every 0.5 s
122
Colour
State
On
Blinking
Green
Flashing
Off
On
Yellow
Off
On
Blinking
Red
Flashing
Off
On
Blinking
Yellow
Flashing
Off
On
Red
Blinking
Off
On
Red
Off
Flashing: on/off every 0.1/0.9 s
Description
Drive-based safety is initialised faultlessly.
Drive-based safety is initialised faultlessly. Internal
communication to the basic device is not possible.
Drive-based safety is in service status.
For exiting, parameterise the drive-based safety.
Drive-based safety is not initialised.
Acknowledgement is not possible.
Controller enabled
Non-safe display "STO"
System error
Trouble
Warning
Error-free operation
Request of an acknowledgement for the restart or the
parameter set adoption
SS1/STO active
SS2/SOS active
No stop function active
Safety bus error:
Communication is not possible.
Acknowledgement is possible.
Safety bus error: no valid configuration.
Safety bus: error-free operation.
Drive-based safety is not accepted by the basic device (see
notes in the instructions for the basic device).
Drive-based safety is correctly recognised by the basic device.
EDK94SH366 DE/EN/FR/ES/IT 3.1