Step
Task
Install the RJ-45 copper cable that is shipped with the system into the console
1
port.
CAUTION: You must install a straight-through RJ-45 copper cable
(a standard Ethernet cable) into the console port. This is different from
many other implementations that require an Ethernet crossover cable (or
rollover cable). If connecting to a terminal server and using a crossover
cable, daisychain another crossover cable to effectively get a straight-
through cable connection. Many console terminal servers use octopus
cables that are crossover cables. To accommodate the octopus cable,
connect an additional crossover cable, as above, to effectively install a
straight-through cable.
If necessary, connect the RJ-45/DB-9 adapter that is shipped with the system to
2
the end of the RJ-45 cable that will connect to your terminal.
Set your initial console terminal settings to match the default console settings on
3
the switch.
9600 baud rate
No parity
8 data bits
1 stop bit
No flow control (console port only)
After establishing a connection, you can modify the settings to match at each
end of the connection.
S25P only: If you use the console port to download software to the switch, you
4
will probably want to raise the console baud rate. Establish a connection with
the default settings to verify the connection. Then use the lineconfig command
to access the Line Config mode, and use the serial baudrate command to raise
the baud rate on the console port. (Match the settings in your terminal access
program.)
Accessing the Console Port
Connect the RJ-45/DB-9 adapter that is shipped with the S25P system to the RJ-
45 cable.