BEFORE INSTALLATION, CHECK THE FOLLOWING
* That the voltage, cable section and rating of the magnetothermal circuit breaker (3) (20A) are correct
for each model. And is accessible, omni polar, and with a contact separation of more than 3mm.It is
advisable that the installation have a differential switch (RCD) with a rated residual operating current
that does not exceed 30 mA.
* That the drainage pipe (4) has a minimum diameter of 35mm.
* That the main tap (5) has a 3/8 Gas thread.
NOTE: Both the electrical installation and the water installation must be in accordance with current
legislation in the place of installation.
1.- To make level the machine by means of the support feet
NOTE: For security reasons the maxima inclination does not have to exceed 1º with respect the
horizontal.
2.- Place the products as shown in the drawing (depending on the models, the pump motor (8), is located
inside the machine). In this case the pipe (A) is connected directly to the lower tap (6c) of the water
purifier (6).
NOTE: The grinder may be installed on either side of the machine.
ATTENTION: The cables for connection to the mains and the pump (in
models with the pump installed outside the machine) are in the lower
front part of the machine.
To pull out the cables to connect to the mains, proceed as follows:
remove the cover (1) and the lower tray (2), cut the ties securing the
cables to the chassis, then replace the cover (1) and the lower tray (2)
in their place.
3.- Connect the drainage pipe (B) to the funnel (2p) on the machine and the drainage pipe (4).
4.- Connect the pipe (short flexible tube) (C) between the main tap (5) and the upper tap of the water purifier (6b).
5.- Connect the pipe (short flexible tube) (D) between the lower tap of the purifier (6c) and the inlet to the
pump (8a). (According to model)
WARNING: – Do not reuse old drain tubes and connecting hoses from the previous installation. To ensure the
correct functioning of the machine, only use the tubes and hoses provided in the box.
The machine has a check valve located in the water inlet pipe.
NOTE: Before connection to the pump inlet (8a), open tap (5) and allow water to circulate through the
purifier system (6) for 2 minutes to eliminate any possible dirt remaining in the circuit.
6.- Connect the pipe (long flexible tube) (A) between the machine inlet and the output from the pump (8a).
7.- Open the main tap (5) and check that there are no leaks in the circuit.
8.- Connect the cable (E) to the pump motor connection box (8c). (According to model)
9.- Connect the cable (F) to the thermo-magnetic switch (3) (20A), in the following order: First the mass
cable, then the cables of the active part; and in the case of having to disconnect at any time, effect the
inverse operation, that is, first the cables of the active part and then the mass cable
NOTE: Make sure that the earth connection is correctly installed and in accordance with current legislation.
VERY IMPORTANT.- Before arming the magnetothermal circuit breaker (3), position switch (2l) on the
machine in "2" (OFF
10.-Arm the magnetothermal circuit breaker (3), positioning it in the "ON" position.
11.-MACHINES WITHOUT AUTOMATIC LEVEL: Fill the machine with water by pressing the control of the
fill tap (2m) until the level reaches 3/4 of the height.
MACHINES WITH AUTOMATIC LEVEL: Place the switch (2l) in the "2" (OFF
machine will automatically begin to fill with water until reaching the ideal level. On the machines equipped
with the boiler level indicator lights (2e), the upper green light indicates the level is correct, the lower red
light indicates boiler
refill.
part (2e)
the symbol lights up when the machine is refilling.
INSTALLATION
)
On the models equipped with the level indicator lights located on the left upper
9
:
GB
) position. The