Installation

3.
Installation
3.1

Safety instructions for installation

D WARNING!
Hazard through disregard of the installation instructions!
This chapter contains important information for the safe
installation of the device.
☞ Read through this chapter carefully before installing the
device.
☞ Follow the safety instructions.
☞ Carry out the installation as described.
y Installation only by qualified specialist personnel.
D "1.2 Authorised target groups" (page 92).
y Electrical work only to be undertaken by qualified
electricians.
D "1.2 Authorised target groups" (page 92).
y Installation requires two persons.
y When working at heights, ensure good stable footing
(e.g. stable stepladder).
y The hob and other parts that can be touched must be
allowed to cool prior to installation.
y Store the film or other parts of the packaging in a location
which is inaccessible to children.
y The device must be in an undamaged and fault-free
condition prior to installation.
y Cables must not be kinked, crushed or damaged.
y Never open the fan housing.
y The power supply voltage must match the voltage
information quoted on the ratings plate.
D "2.5 Technical data" (page 94).
y Ensure that the power supply is stable and remains so
prior to the installation.
Connect the power supply only when instructed to do so
in the installation instructions.
6003417_a – 26.09.2017
3.2

Requirements for the installation location

D WARNING!
Risk of death due to improper installation!
Disregard of the ambient conditions can lead to hazardous
situations, e.g. in the handling of electrical power or gas.
☞ Make sure that the requirements for the installation
location are complied with.
y Do not install in potentially explosive atmospheres.
y With simultaneous use of a heating point which uses air
from the room as its oxygen supply (e.g. chimneys):
y A safety device is absolutely essential.
y The safety device (e.g. under-pressure monitor P4,
inspected in accordance with DIN 18841:2005-12 TÜV
and in accordance with DVGW-VP121) must prevent
gases being drawing to the room.
y An approval for commissioning (e.g. from a
chimneysweep) must be available.
y Installation is only permitted on structural building
elements capable of bearing the load (solid structure).
y If installed above fireplaces that use solid fuels (e.g. coal
stove):
The fireplace must have a sealed cover which cannot be
removed. Otherwise there is a fire risk due to flying sparks.
Applicable legal and country-specific regulations must be
observed.
y The air flowing out must be able to dissipate unimpeded.
Do not impede the air flow, e.g. through the installation of
objects on or above the device.
y Make sure that the building electrical supply is properly
earthed.
y The power supply voltage present must match the
voltage information quoted on the ratings plate.
y There must be an electrical power outlet in the vicinity of
the device installation.
y The mains plug must be accessible after the installation of
the hood.
 Country-specific, legal provisions must be observed.
3.3

Requirements for recirculated air mode

y Filter filling freely accessible for changing.