Determine the required cross section of the cable in relation to the cable length
according to fig. 7, page 6.
Key to fig. 7, page 6:
Coordinate axis
l
A
NOTICE!
Make sure the polarity is correct.
Connect your refrigerator to a plug socket which is fuse-protected with at least
15 A (at 12 Vg) or 7.5 A (at 24 Vg) (fig. 8 1, page 6).
Connect the red cable (fig. 8 rt, page 6) to the positive terminal of the battery.
Connect the black cable (fig. 8 sw, page 6) to the negative terminal of the
battery.
7.6
Connecting the refrigerator to AC voltage
D
DANGER! mortal danger!
• Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
• If you are operating your refrigerator on board a boat with an
AC mains connection using a shore connection, you must install a
residual current circuit breaker between the AC mains supply and
the refrigerator.
Seek advice from a trained technician.
Connecting the ACDC version to AC voltage
Proceed as follows when you connect the refrigerator to the AC supply:
Plug the connector into the AC socket (fig. 9 1, page 6).
EN
Installing and connecting the refrigerator
Meaning
Cable length
Cable cross section
Unit
m
mm²
19