Displays

5.2
The TESTER-A2, according to the test selected,
offers 4 possible displays:
complete numeric;
analog bar;
time-graphic;
hit-graphic.
5.2.1
Complete numeric display
In this display the following resistances are
displayed simultaneously:
• the main resistance (and relative threshold);
• resistances measured with the tester probe P
(and relative threshold);
• leakage resistances (and relative threshold).
Selected test
Current display
Battery level status
Main value
Threshold of main value
Resistances measured with the tester
probe P
Threshold of resistances of tester probe P
Leakage resistance
Threshold of the leakage resistance
F
E
D
AVERO
LECTRONIC
ESIGN
 
Pag. 5 / 36
In the diagram above, the epee tip is pressed,
which shows a value of 0.7Ω, inferior to the
threshold of 2.0Ω: the tip is in compliance.
5.2.2
Display with analog bar
In this display only the main value is shown
(normally, the weapon's tip contact).
Under the numeric value of resistance, an analog
bar is displayed with instantaneous updating, with
graphic display of the threshold value.
Selected test
Current display
Battery level status
Main value
Value 0Ω for the bar
Threshold point for the analog bar
Threshold value
In the diagram above, the epee tip is pressed,
which shows a value of 3.0Ω, greater than the
threshold of 2.0Ω; the numeric value is shown
highlighted
signifying that there are problems with
the tip.
For the T-SHIRT test (see par. 5.12), the bar shows
two threshold values.
00899-M01-03-ML - Manuale TESTER-A2