9. Specifications
Model 632.51
Pressure limitation
Steady
Fluctuating
Short time
Temperature effect
Wetted materials
Process connection with measuring
chamber, pressure element
Sealing
Non-wetted materials
Case, movement, bayonet ring
Dial
Pointer
Window
Ingress protection per IEC/EN 60529
For further specifications see data sheet PV 26.06
Models DPGS43.100, DPGS43.160
Pressure limitation
Steady
Fluctuating
Short time
Temperature effect
Wetted materials
Process connection
Pressure element
Non-wetted materials
Case, bayonet ring
Movement
Dial
Pointer
Window
Ingress protection per IEC/EN 60529
For further specifications see data sheet PV 27.05
Pressure gauges with inductive contact model 831, for hazardous areas
Full scale value
0.9 x full scale value
50 x full scale value
When the temperature of the measuring system deviates
from the reference temperature (+20 °C): max. ±0.6 %/10 K
of full scale value
Stainless steel 1.4571
PTFE
Stainless steel
Aluminium, white, black lettering
Aluminium, black
Laminated safety glass
IP54
Full scale value
0.9 x full scale value
minimum 10 x full scale value, max. 25 bar
When the temperature of the measuring system deviates
from the reference temperature (+20 °C): max. ±0.5 %/10 K
of full scale value
Stainless steel 316Ti (1.4571)
≤ 0.25 bar: Stainless steel 316L
> 0.25 bar: NiCr alloy (Inconel)
Stainless steel
Brass
Aluminium, white, black lettering
Aluminium, black
Laminated safety glass
IP54; option: IP65