Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

8. Maintenance

BOILER SCALE CLEANING
-
Make sure that appliance is un-
plugged and has cooling down
A - Remove the iron board cloth.
B - Remove two screws that fi x the
detachable boiler.
C - Empty the exceed water from the
water tank.
D - Turn over the detouchable boiler
and slowly unscrew using the
equipment key.
E - Using a funnel fi ll the boiler with 0,5
litres of tap water, screw back the
nut and energetically shake it.
F - Open again and empty the boiler
from residual scale.
Repeat operation D and F at least
three times.
-
Before close the scale cleaning
cap check if gasket is deformed
or broken, than make sure that
cap is closed tightened
To replace detachable boiler you
have to procede on the following
way:
G - Place the detachable boiler in verti-
cal way to iron board and with light
pressure towards the bottom so the
assembling will be correct.
H - Screw again the detachable boiler
I - Replace the cloth.
27

Publicité

Table des Matières
loading

Table des Matières