COMMAND ANALYSER MODE (IM)
This function allows you to view any DUOX command transmitted by any device on the
installation.
These commands are stored in the programmer's internal memory, up to a maximum of
100 entries.
To capture the commands, follow these steps indicated in the diagram:
A new command is
made
Upon reviewing the stored entries, the last command registered appears first.
Some commands are sent several times a day as a security measure up against a loss
of data, all remaining registered.
The contiguously repeated commands are shown alternating a dash (-) and asterisk (*)
Return to the main menu.
ESC
2. ANALYZER
OK
* * * * *
WAIT COMMAND
A command is made...
DISABL-CHANNEL 1
00F010 - FFF0FF
OK
Full memory (100
commands)
MEMORY FULL
OK
DISABL-CHANNEL 1
00F010 - FFF0FF
We start from option 2 ANALYSER from the MAIN
MENU
The device remains available to receive commands.
WAIT COMMAND blinks.
The command appears on the display and is saved in the
memory.
In the bottom linte the origin and destination adresses
appear, sespectively.
DISABL-CHANNEL 1
00F010 - FFF0FF
Review the
commands registered
via the arrows
Review the
commands registered
via the arrows