Fermax DUOX Manuel D'installation page 45

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BLOCK GUARD UNIT DETECTION (IM)
This function allows you to detect the existence of guard units configured as BLOCK GUARD
UNIT within the installation, along with their number.
For this, follow these steps indicated in the diagram:
1. DETECTOR
1. DETECTOR
ALL GUARD UNITS
No guard units have
been detected
TEST RESULT:
NO GUARD UNITS
Exit this function and return to the GUARD UNIT DETECTION menu
ESC
ESC
We start from the BLOCK GUARD UNIT DETECTION
option on the GUARD UNIT DETECTION menu:
BLOCK PANEL
OK
1 2 3
4 5 6
BLOCK: 00
7 8 9
0
OK
Start testing the 10 possible guard unit numbers that may exist
in the indicated block.
GUARD UNIT
00 00
The two digits to the left indicate the block number being tested,
and the two right ones the panel number.
After having completed the scan, you can present one of these 3
results:
All 10 guard units
have been
detected
TEST RESULT:
TEST RESULT: ?
TEST RESULT: ?
Enter the block number you wish to test.
Values admitted: 00 to 09
ESC
Only some guard units have been detected.
Choose if you want to view the detected or
undetected ones.
OK
DETECTED
OK
NO DETECTED
GUARD UNIT OK:
00 07
GUARD UNIT NOK:
00 04
The guard units
detected are
displayed
The guard units
NOT detected
are displayed

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3254

Table des Matières