Technical Data

Repair station
Dimensions L x W x H (mm)
Dimensions L x W x H (Inch)
Mains supply voltage
Power consumption
Safety class
Fuse
Temperature (Tool dependent) °C
Temperature (Tool dependent) °F
Temperature accuracy °C
Temperature accuracy °F
Temperature accuracy Hot air °C
Temperature accuracy Hot air °F
Temperature stability °C
Temperature stability °F
Equipotential bonding
Display
USB port
Pump (Intermittent mode (30/30) s)
Additional vacuum pump
WR 3M
273 x 235 x 102
10.75 x 9.25 x 4.02
230 V ~ 50/60 Hz | 240/120 V ~ 50/60 Hz
120 V ~ 60 Hz | 100V ~ 50/60 Hz
400 W
I, antistatic housing
III, Soldering tool
Overcurrent release 230 V; 2,0 A
120 V; 4,0 A
50 - 450
(550)
150 - 850
(999)
± 9
± 17
± 30
± 54
± 2
± 4
Via 3.5 mm pawl socket on back of unit
(delivery form: hard grounded without jack plug)
LCD
The control unit comes with a front-side USB
port for installing firmware updates, configuration
and monitoring.
Max. vacuum 0,7 bar
Max. delivery rate 18 l/min
Max. hot air 15 l/min
Max. vacuum 0,5 bar
Max. delivery rate 1,7 l/min
WR 2
300 W
1,6 A
-
-
49