Weller WR 2: WR 3M Traduction De La Notice Originale page 20

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
Parameter menu
Button lock HAP 200 (HAP LOC)
WR 3M
This function can be used to adjust the factory
button presets of the WXAHP tool.
The HAP 200 is switched on the first time the
button is pressed and switched off the next time
the button is pressed.
Perform. Mode
The function determines the heating characteris-
tics of the soldering tool to achieve the set tool
temperature.
Resetting to factory settings (FSE)
Select the menu option FSE in menu 1.
WR 2: Press and hold down button ┌ 2 ┐.
1. Open special functions menu „1" (push UP & DOWN buttons simultaneously for 2sec.)
2. Press and hold down button ┌ 2 ┐.
3. Then press the UP and DOWN buttons simultaneously. „FSE" appears on the display.
(Factory Setting Enabled).
The repair station is now reset to the factory settings.
Reset the calibration values to the factory settings
1. Open special functions menu „2" (push UP & DOWN buttons simultaneously for 4sec.)
2. Select menu option „FCC".
2. Press and hold down button ┌ 2 ┐.
4. Then press the UP and DOWN buttons simultaneously. „FSE" appears on the display.
(Factory Setting Enabled).
The repair station is now reset to the factory settings.
WR 3M: Press and hold down button ┌ 3 ┐.
1. Open special functions menu „1" (push UP & DOWN buttons simultaneously for 2sec.)
2. Push button ┌ 3 ┐and hold it down.
3. Then press the UP and DOWN buttons simultaneously. „FSE" appears on the display.
(Factory Setting Enabled).
The repair station is now reset to the factory settings.
Reset the calibration values to the factory settings
1. Open special functions menu „2" (push UP & DOWN buttons simultaneously for 4sec.)
2. Select menu option „FCC".
2. Push button ┌ 3 ┐and hold it down.
4. Then press the UP and DOWN buttons simultaneously. „FSE" appears on the display.
(Factory Setting Enabled).
The repair station is now reset to the factory settings.
48
Option
Description
OFF
Deactivated (factory setting)
ON
HAP LOC activated
Option
Description
LO
Slow heating
HI
rapid heating
Menu access
- 2 -
Menu access
- 2 -

Publicité

Table des Matières
loading

Table des Matières