Dovre VINTAGE 35GA Type C11 Mode D'emploi page 58

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 96
pipe. You can also convert the existing pipe into a con-
centric pipe using a single-wall flexible hose and the
right pipe reducers. There is a conversion kit for this.
See the chapter "Installation requirements" for the con-
ditions under which this conversion is permitted.
The conversion kit must be ordered separately.
The following parts are required to convert an existing
flue into a closed system; see next figure.
1
The hearth or stove to be connected
2
Concentric duct, 100/150 mm, modular
3
Installation plate inside, square 300 mm
4
Single-wall slide, round diameter 97 mm
12
5
6
7
8
9
10
11 Roof sleeve
The conversion set consists of parts 3, 4, 5, 7 and 9.
Follow the instructions below for assembly and see
the figure above.
1. Lead the flexible hose (6) through the existing pipe
2. Attach the slide (4) to the lower end of the flexible
3. Keep the bottom of the slide even with the bottom
4. Attach the installation plate-outside (9) to the flexi-
5. Attach the installation plate-outside (9) watertight
6. Install the roof sleeve (11) and secure it with the
7. Attach the installation plate-inside (3) gastight on
09-20020-194
8. Place the stove (1) as indicated in the chapter
9. Connect the stove with the lower end of the flue
Parker screws (4 pc)
Flexible stainless steel 316L hose, single-
wall round diameter 100/107 mm (heat resis-
tance 600°C)
Stainless steel hose clamp reach diameter
90 to 165 mm
Existing chimney or flue pipe
Installation plate outside, square 300 mm
Clamping strap (included in delivery of part
11)
(8).
hose and secure it with two Parker screws (5).
of the pipe or the ceiling. Cut the flexible hose at
approximately 100 mm above the chimney cap.
ble hose, clamp it with a hose clamp (7) and
secure it all with a Parker screw (5).
to the chimney cap with silicon sealant and stain-
less steel screws.
clamping strap included in the delivery (10).
After the roof sleeve is installed, the slide (4)
should extend about 100 mm under the pipe or
ceiling.
the bottom of the flue or on the bottom of the cei-
ling with silicon sealant and stainless steel
screws.
"Installation requirements".
using concentric components (2). All components
Subject to change because of technical improvements

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vintage 35ga type c31Vintage 35ga type c91Vintage 50ga

Table des Matières