Monitoring operation

The operating status of the unit can be monitored via the RDM monitor of the controller. The layout of the RDM
monitor may vary depending on which RDM controller is used. As soon as a sensor value of the unit leaves
the admissible range of values, a corresponding note or error message is displayed in the field "Last Status
Message".
Sensor values of the Underwater LED Driver/DMX/02
Sensor
Description
1
Voltage
Applied input voltage
Sensor values of the LED spotlights
Sensor
Description
1
Electronic
Temperature monitoring
temperature
7

Remedy of faults

Malfunction
No spotlight is lit.
One spotlight is not lit.
An individual spotlight does not light up in the
desired colour.
Luminous intensity of a spotlight is insufficient.
24
Permissible range
21.6 V DC ... 28 V DC
(approx. 24 V ±10 %)
Permissible range
-10 °C ... +75 °C
Cause
No supply voltage
The luminous intensity of all spotlight LEDs is
0 %.
Underwater LED driver, DMX controller or
switching power pack defective
Spotlight not connected.
The luminous intensity of all spotlight LEDs is
0 %.
Spotlight or underwater LED driver output
defective
Underwater LED Driver /DMX/02 is not compa-
tible with the spotlight.
Incorrect spotlight setting
LED of the spotlight defective
Spotlight LEDs excessively dimmed
The luminous intensity has been automatically
reduced due to excessive temperature in the
spotlight.
Spotlight glass soiled
Error message
The permissible range is gone below:
− "The input voltage must be at least 21 V."
The permissible range is exceeded:
− "The input voltage may not exceed 28 V."
Error message
<> 0
"Temperature error"
Remedy
Check all cables and connections.
− Change the spotlight setting.
− Check the luminous intensity of the LEDs
and the DMX address.
Determine which unit is defective and proceed
with the malfunction remedy according to its
instruction manual.
Check connection between spotlight and LED
driver.
− Change the spotlight setting.
− Check the luminous intensity of the LEDs
and the DMX address.
− Connect the spotlight to a different output on
the underwater LED driver.
− Have spotlight repaired.
− Have underwater LED driver repaired.
Use underwater LED driver /DMX/02, versi-
on 2.0. The following spotlights are only
compatible with version 2.0:
− ProfiLux LED 110/DMX/02 (56267)
− ProfiPlane LED 110/DMX/02 (56298)
− ProfiLux LED Spot 1500/DMX/02 (56388)
− ProfiLux LED Flood 1500/DMX/02 (56391)
− Change the spotlight setting.
− Check the values for the LEDs, DMX address
and configuration mode.
Have spotlight repaired.
− Change the spotlight setting.
− Check the values for the LEDs, DMX address
and configuration mode.
No measure required.
Clean spotlight glass.