Putting Into Operation; Appliance Dimensions; Recess Dimensions - V-ZUG Magnum 2 60i eco Notice D'installation

Réfrigérateur et congélateur
Masquer les pouces Voir aussi pour Magnum 2 60i eco:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Putting into operation

NOTICE
Risk of damage due to condensation!
When stacking multiple appliances there is a risk of conden-
sation damage.
u Do not stack refrigerators or freezers.
WARNING
Blocked ventilation openings pose a risk of fire and damage!
u Always keep the ventilation openings clear. Always ensure
that the appliance is properly ventilated!
In the event that the appliance is damaged, contact the
q
supplier immediately before connecting to the mains.
The floor at the site must be flat and level.
q
Do not install the appliance in a location where it is exposed
q
to direct radiation of the sun, next to a cooker, heater and
similar.
Do not install the appliance alone: it is best to work together
q
with two or more people.
The more R 600a refrigerant there is in the appliance, the
q
larger the room in which the appliance is standing needs to
be. In rooms that are too small, a flammable mix of gas and
air may be created if there is a leak. According to the EN 378
standard, every 11 g of R 600a refrigerant requires at least
1 m
space in the room for the appliance. The amount of
3
refrigerant in your appliance is on the type plate inside the
appliance.
If the appliance is installed in a very damp environment,
q
condensed water may form on the outside of the appliance.
Always make sure that there is good ventilation - both at air
inlet and outlet - at the site of installation.
After installation:
u Remove protective films, adhesive tapes and transport lock
parts etc.
Note
u Clean
the
appliance
Chapter "Cleaning the appliance").

2.3 Appliance dimensions

18
(see
Operating
Instructions,
Magnum 2 60i eco, Jumbo
60i, Iglu 60i

2.4 Recess dimensions

The appliance is built-in and therefore completely enclosed by
a kitchen unit. The kitchen unit concerned must be built exactly
to the prescribed dimensions and allow for sufficient ventilation,
both at air inlet and outlet, to ensure proper appliance opera-
tion.
Fig. 2
D
(mm)
Magnum
2 60i
1772
eco,
Jumbo
1788
60i, Iglu
60i
The specified energy consumption applies to a unit depth of
560 mm. The appliance will work properly at a unit depth of 550
mm, but at a slightly higher energy consumption.
u In the case of Side-by-Side installa-
tion, two appliances next to one
another, build the appliances into
separate kitchen units.
u Check the wall thickness of the adjoining cabinets: it must
be min. 16 mm thick.
u Only install the appliance in robust, stable kitchen units.
Secure the units against tipping.
u Align the kitchen unit using a spirit level and marking square
and if necessary compensate with shims.
u Ensure that the floor and walls of the unit are at right angles
Fig. 1
to one another.
A (mm)
B (mm)
559
544
E
F (mm)
G
(mm)
(mm)
(mm)
min.
560
550,
min.
recom-
500
570
mended:
560
* Depending on model and options
C (mm)
1770
H
J
(mm)
min.
max.
40