SKF LAHD 500 Mode D'emploi page 7

Masquer les pouces Voir aussi pour LAHD 500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
3. Adjust the support bracket which holds the oil leveller to approximately
50 mm (2 in) below the required oil level.
4. Separate the lower and the upper reservoirs from each other.
5. Connect the lower reservoir to the support bracket by means of the two
fixation nuts at the bottom of the oil leveller.
6. Adjust the height of the oil leveller so that the required oil level is between the
two lines marked on the lower reservoir.
7. Measure and cut the plastic tube to the adequate length.
8. Prepare both ends of the tube with the swivel connectors. Start by sliding the
swivel adapter (with the thread facing outwards) on top of the tube. Insert the
copper sleeve into the tube and slide the copper ring on top of the sleeve.
Tube & coupling assembly
9. Thread the two connection couplings (G 1/2) onto the oil leveller and the
application and connect the tube. Firmly tighten the swivel adapters.
10. Ensure there are no bends or kinks in the tube preventing the oil to flow freely
from the oil leveller to the application.
SKF LAHD 500-1000
level
oil
oil
level
level
oil
oil
level
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lahd 100

Table des Matières