Trouble shooting
H90
Wheel acceleration was too slow, or braking was too
weak after a measuring run. If the main shaft does
not reach the required rpm, check whether the brake
was activated or whether the mass of the wheel is too
great. In this case:
Release the brake.
Make sure that the shaft with the wheel clamped on it
can rotate freely.
Turn the wheel by hand, then run the START.
If the error cannot be eliminated, call the service team.
H91
Rpm variation during measuring run. The brake may
be ON.
Release the brake.
Make sure that the shaft with the wheel clamped on it
can rotate freely.
Repeat the run.