The air valve of the skimmer must be throttled until air is independently sucked through the
ozonizer.The Skimmer can be operated with ozone up to max. 50 mg/h per pump. One air
connection of the ozoniser should be connected via a suitable silicon hose to the protein
skimmer pump. The air is automatically sucked in the ozoniser by the skimmer pump.
Should the skimmer performance deteriorate please check the ozoniser for blockage.
Safety information:
The maximum ozone quantity of 50mg/hour per pump must not be exceeded.
-
The air passage can be reduced as a result of dust deposits in the ozonizer. This can
-
result in an increase in the water level in the skimmer, which - in extreme cases - can
overflow. To avoid this, check the ozonizer regularly to make sure that there are no
deposits of dust. If necessary, clean it.
Never breathe in free ozone.
-
The ozonizer may not be directly connected to the air valve or silencer.
-
In order to avoid water damage, the ozonizer must be placed high enough to ensure
-
that no water can penetrate it when the skimmer pump is switched off.
c) Water level adjuster
d) Skimmer cup