US/CDN
1
INTRODUCTION
SANISTAR
is a wall hung toilet with an
®
internal macerator/pump to which you can
also connect a sink.
The SANISTAR
can only be installed with
®
the special support bracket supplied.
SANISTAR
is meant for use in residencial
®
applications.
Installed and used correctly, SANISTAR
will give you reliable and consistent service.
«WARNING» This is a general warning that
failure to follow instructions could result in poor
functioning of the unit.
PRINCIPLES OF OPERATION
SANISTAR
is controlled by an electronic
®
program with two functions.
• It has a macerating and pumping function.
To begin press on either side of the push
button (light grey: small flush, dark grey:
large flush) integrated to the bowl.
• The pump cycle cleans the washbasin
waste. This is an automatic operation that
will activate as long as water from the
washbasin enters the unit.
2
LIST OF ACCESSORIES SUPPLIED :
see drawing 2
3

DIMENSIONS :

see drawing 3
4

TECHNICAL DATA

Application
1 WC + 1 sink
Maximum vertical pumping
Voltage
Frequency
Normal power rating
Maximum current consumption 9 A
Maximum water temperature
Electric class
Degree of protection
Net weight (with frame)
Horse power
WARNING:
Only installations conforming to
the above specifications are acceptable.
5
PERFORMANCE CURVE :
see drawing 5
6
VERTICAL/HORIzONTAL
PUMPING COMBINATIONS :
see drawing 6
7
INSTALLATION
PREPARATIONS
WARNING:
Before proceeding with the
installation of SANISTAR
, ensure that the
®
wall is sufficiently strong to support the unit.
(Each fastening should have a
tensile strength of 120 kg (264Ibs)).
Note that the SANISTAR
can handle up
®
to a maximum of 250 lbs (weight limit).
PREPARING THE SUPPORT FRAME
7a
Separate the bowl and template
1 -
the frame (shipped together for transit
purposes).
2
- Assemble the threaded rods
nuts
B
drawing
3
- Adjust nut on threaded rod to 2-inches
®
(50 mm) + x the wall thickness (e.g. wall
board plus tiles etc.). See drawing
Adjust the lateral spacing of the rods so
4 -
that they line up with the holes in toilet.
Tighten the nuts fully.
5 -
Fit the plastic sleeves/inserts
6 -
the treaded rods and tape them down
temporarily. (They protect the ceramic
from the metal threads).
SETTING THE HEIGHT OF THE
7b
SUPPORT FRAME
1
- Place the frame against the wall.
2
- Adjust to a comfortable height using the
vertical threaded feet. (See drawing
(Note ADA requirements is minimum
17-inches from floor to to top of toilet
seat. Adjust the feet from floor to center
of threaded rod to 13 1/2-inches).
4
- Adjust the horizontal seating of the
bowl support.
5
- Fully tighten the feet rod nuts.
ATTACHING THE FRAME TO THE
7c
WALL
9 feet
110-115 V
1
- Mark the screw holes with a pencil.
60 Hz
2
-
WARNING:
960 W
vertical, shim the frame with washers
(as per drawing
95°F
3
- Drill a 1/4-inch pilot hole.
I
IP44
4
- Use 6 (3/8 x 3-inch) lag screws to
68 Ibs
fasten frame to the stud wall.
0,4 HP
5
- Use all 6 holes to fasten the frame
to the wall.
6
WARNING:
-
The distance between the supporting
wall and the front of the support frame
should not exceed 4-inches (100 mm).
The frame should fit flat against the wall.
WATER SUPPLY
7d
Install a 1/2-inch water supply.
1 -
The water supply pipe must be fitted in
2 -
the upper part of the frame.
The pipe should terminate with a stop
3 -
valve (1/2-inch sweat x 3/8-inch
compression) with the handle of the
stop valve just visible below the top of
the frame.
from
E
/with
A
/and washers
as per
C
.
7a
7a
onto
D
7a
If your wall is not perfectly
#2).
7c
The water supply pipe should be
4 -
fastened with clamps against the wall
in order to avoid any movements while
connecting the device.
For correct rinsing of the bowl, the
5 -
water pressure must be minimum
25 PSI (1,7 bar).
.
DISCHARGE CONNECTION
7e
1 -
The discharge pipe should be either
copper or CPVC or PVC solvent weld
pipe in 1-inch diameter.
2 -
Put the end of the pipe through the
upper part of the frame.
IMPORTANT:
Use only long sweeping
elbows for the discharge pipe or a couple of
45 degree elbows back to back when chan-
ging direction. Do not use 90 degree elbows.
CONNECTION OF SINk
7f
1 -
Connect sink waste via 1 1/4-inch ABS
).
or PVC pipe.
2 -
Feed the waste pipe through either the
left or right hand side holes provided.
3 -
IMPORTANT:
The drain pipe coming
from the sink should connect into the
special connector (provided).
ELECTRICAL CONNECTION
WARNING: risk of electric shock- this pump
is supplied with a grounding conductor and
grounding type attachment plug to reduce
the risk of electrical shock. Be certain that it
is connected only to a properly gounded -
type receptacle.
• Plug the electrical cord into a receptacle
protected by a 15 Amp GFCI circuit brea-
ker.
• Due to service requirements this electrical