6. Device overview

6.1 Versions

6.1.1 Device variant ELMON inductive 77
The stationary coil core is connected to the safety relay via a cable. The safety relay can be screwed flat to a
base with 4 screws or snapped onto a 35 mm mounting rail. In the case of rail mounting, it is also possible
to cut off the bolt-on feet.
6.1.2 Device variant SPK 77
The stationary coil core is integrated in the safety relay. This device variant is installed directly on the trans-
mission cable via a bracket.

6.1.4 Variant E

Control output as high-side switch and low-side switch
+
High
Side
OUT_H
Switch
OUT_L
Low
Side
Switch
_

6.1.5 Variant W

Control output as 8k2 resistance output
R 11
R 12
resistor
8k2
While in the idle state, the resistance between the two connections is approximately 8.2 kΩ. If actuation of
the safety edges is reported, the resistance is less than 100 Ω. In the event of a fault or interruption of safety
edges, the resistance is greater than 100 kΩ.
6.1.6 Variant R
Control output via semiconductor relay
13
14
Semiconductor
relay
Alternative or parallel use of the outputs possible
No galvanic separation
Cat. 3 (internal testing)
DC supply
Galvanic separation
Cat. 3 (internal testing)
Adaptation to the controller may be necessary.
AC / DC supply
Galvanic separation
Only Cat. 2 possible
AC / DC supply