ELMON inductive 77 / SPK 77 Inductive signal transmission system

6.2 Signal indicators

SCE
stationary
open
TEST
SCE
stationary
close
During the output of an error message, the number of output pulses indicates the error:
Pulse
Error message
1
Voltage supply outside of the valid value range
2
Output control Open faulty
3
Output control Close faulty
4
Data transmission with microcontroller faulty
5
ELMON inductive transmission error

6.3 Connection terminals

9
SCE
SCE
ELMON
inductive
open
close
Uin, Gnd:
DC voltage supply for device variant ELMON inductive 77 E. A positive cable is connected to Uin, and the
negative cable is connected to Gnd.
B1, B2:
AC or DC voltage supply for device variant ELMON inductive 77 R or ELMON inductive W. The polarity of the
supply voltage is not critical.
24
SCE
transmit
open
SCE
transmit
close
FUN
Plug-in screw terminals or cable connection
1
E L M O N
i n d u c -
tive 77 E:
1: TST_MOD
2: TST_COM
3: TST_SIG
4: CLOSE_OUT_L
5: OPEN_OUT_L
6: CLOSE_OUT_H
7: OPEN_OUT_H
8: Uin
9: GND
SCE Stationary open
actuated (on) - interrupted (flashes)
SCE Stationary close
actuated (on) - interrupted (flashes)
SCE Transmit open
actuated / interrupted (on)
SCE Transmit close
actuated / interrupted (on)
FUN
Functional test (off briefly)
Error message (pulse output)
TEST
Test active (on)
ELMON inductive 77 R /
ELMON inductive 77 W:
1: TST_MOD
2: TST_COM
3: TST_SIG
4: CLOSE_OUT1
5: CLOSE_OUT2
6: OPEN_OUT2
7: OPEN_OUT1
8: B1
9: B2
Colors of wires:
1 = pink
2 = blue
3 = gray
4 = green
5 = yellow
6 = brown
7 = white
8 = red
9 = black