Working
8.1
Handling
Hose store: after finishing work, you can feed the
suction hose through the recess [8-3] and place it
in the hose store. You can do the same with the
mains cable through the other recess [8-2].
SysDoc Systainer attachment system: a Systainer
can be attached to the storage area via the two
slides [8-1].
8.2
AUTOClean - Cleaning the main filter
(only versions with AutoClean)
Only in conjunction with disposal bag (com-
pliance with dust class 'M'). Not suitable for
wet extraction!
Automatic cleaning
Adjust the frequency using the rotary knob [1-8].
Only CTM for 36 E AC-LHS: switch on using the ro-
tary knob [1-8].
Manual cleaning
Turn the switch [1-11] to the AC symbol.
Full manual cleaning
Cover the end of the nozzle or suction hose with
your hand or closing slide CT-VS (497926) for 2
seconds.
Turn the switch [1-11] to the AC symbol.
8.3
Special features of the CTM 36 E AC- LHS
To use the mobile dust extractor in combination
with the PLANEX:
Use kink-resistant suction hose D 36 mm x 3.5
m-AS.
Use a special suction sleeve for connecting the
PLANEX.
Use closing slide CT-VS between the intake
opening [1-2] and suction hose.
Attach the tool holder.
Always use with a disposal bag!
8.4
Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
Use a filter or disposal bag when extracting haz-
ardous materials!
Do not use the machine if the volumetric flow
monitoring function is inactive.
Observe the following when extracting dust gener-
ated by operating electric power tools:
If the exhaust air is discharged back into the room,
the air renewal rate L within the room must be
sufficient. The volume of air discharged back into
the room must not exceed 50% of the fresh air vol-
ume flow (room volume V
Observe all the relevant regional regulations.
Remember: A moist main filter clogs more quickly
when extracting dry materials. Therefore, dry the
main filter before extracting dust or replace the
damp filter with a dry one.
8.5
Extracting wet materials/liquids
Remove the filter or disposal bag!
Recommendation: use special wet filter
(NF-CT).
The dust extractor stops automatically when the
maximum level is reached.
After wet extraction, allow the main filter to dry!
CAUTION
Escaping foam and fluids
Switch off and empty the machine immediately.
8.6
After finishing work
Only versions with AutoClean: Clean the main
filter automatically or manually (see chapter
8.2).
Switch off the mobile dust extractor and pull out
the mains plug.
Wind up the mains power cable.
Empty the dirt trap.
Close off the extractor opening [1-2] using the
sealing plug [1-1].
WARNING
Hazardous dust
Damage to the respiratory passage
Wipe down the mobile dust extractor and clean
all accessories thoroughly using the extractor
(inside and out) before removing from the work-
ing area.
Parts that you were not able to clean thoroughly
must be sealed in an airtight plastic bag prior to
transportation.
Wear a dust mask!
The machine shall be stored indoors only.