OBJ_BUCH-2439-002.book Page 22 Wednesday, August 19, 2015 9:07 AM
22 | English
Also, air layers with varying temperatures or indirectly received reflec-
tions can affect the measured value.
Troubleshooting – Causes and Corrective Measures
Cause
Temperature warning indicator (b) flashing; measurement not pos-
sible
Measuring tool not within the operat-
ing temperature range between
– 10 °C and +40 °C.
Battery low indicator (a) appears
Battery voltage decreasing (measure-
ment still possible).
Battery low indicator (a) flashing; measurement not possible
Battery voltage too low
All indicators on the display flash
The measuring tool is defective.
The laser beam outlet 9 or the recep-
tion lens 8 are misted up (e.g. due to a
rapid temperature change).
The "Err" indication is displayed after pressing the "HOLD" button
Unreliable measuring result
The target surface does not reflect cor-
rectly (e.g. water, glass).
The laser beam outlet 9 or the recep-
tion lens 8 are covered.
Measuring result not plausible
Obstruction in path of laser beam
The measuring tool monitors the proper function for each measurement.
When a defect is detected, all indicators on the display flash. In this case,
or when the corrective measures listed above cannot correct the error,
have your dealer forward the measuring tool to an authorised Bosch after-
sales service.
2 609 141 294 | (19.8.15)
Corrective Measure
Wait until the measuring tool has
reached the operating tempera-
ture
Replace batteries
Replace batteries
Contact the Customer Service
Wipe the laser beam outlet 9
and/or the reception lens 8 dry
using a soft cloth
Cover off the target surface
Make sure that the laser beam
outlet 9 or the reception lens 8
are unobstructed
Laser point must be completely
on target surface.
Bosch Power Tools