The floor of the installation location must
not give way; if required, reinforce floor. If
the floor is uneven, compensate with
supports.
Distance from wall
When installing the appliance, ensure
that the door can be opened by 90°.
Observe ambient
temperature
and ventilation
Ambient temperature
The appliance is designed for a specific
climate class. Depending on the climate
class, the appliance can be operated at
the following temperatures.
The climate class can be found on
the rating plate. Fig. ,
Climate class
SN
N
ST
T
Note
The appliance is fully functional within
the room temperature limits
of the indicated climatic class. If
an appliance of climatic class SN
is operated at colder room temperatures,
the appliance will not be damaged up to
a temperature of +5 °C.
Permitted ambient
temperature
+10 °C to 32 °C
+16 °C to 32 °C
+16 °C to 38 °C
+16 °C to 43 °C
Ventilation
Fig. #
The air on the rear panel and on the side
panels of the appliance heats up.
Conduction of the heated air must
not be obstructed. Otherwise,
the refrigerating unit must work harder.
This increases power consumption.
Therefore: Never cover or block
the ventilation openings!
Connecting
the appliance
After installing the appliance, wait at least
1 hour until the appliance is switched on.
During transportation the oil in
the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for
the first time, clean the interior of
the appliance (see chapter "Cleaning
the appliance").

Electrical connection

The socket must be near the appliance
and also freely accessible following
installation of the appliance.
m
Warning
Risk of electric shock!
If the length of the mains cable is
inadequate, never use multiple sockets
or extension leads. Instead, please
contact Customer Service for
alternatives.
The appliance complies with protection
class I. Connect the appliance to
220–240 V/50 Hz alternating current via
a correctly installed socket with
protective conductor. The socket must
be protected by a 10 A to 16 A fuse.