Adjusting Air Pressure - Hitachi Koki NV 83A2 Manuel D'instructions Et De Sécurité

Masquer les pouces Voir aussi pour NV 83A2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
(1) DISCONNECT AIR HOSE FROM NAILER.
REMOVE ALL NAILS FROM NAILER.
ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY.
Trigger
Push Lever
(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
Connect the air hose.
Do not load any nails in the Nailer.
THE NAILER MUST NOT LEAK AIR.
Hold the Nailer downward and pull the trigger.
THE NAILER MUST NOT OPERATE.
Do not connect
air hose
2
).
Pull Trigger
— 12 —
(3) With finger off the trigger, depress the push lever
against the workpiece.
THE NAILER MUST NOT OPERATE.
Depress Push Lever
(4) Without touching the trigger, depress the push lever
against the workpiece.
Pull the trigger.
THE NAILER MUST OPERATE
(5) With the Nailer off the workpiece, pull the trigger.
Depress the push lever against the workpiece.
THE NAILER MUST OPERATE.
(6) If no abnormal operation is observed, you may load
nails in the Nailer.
Drive nails into the workpiece that is the same type to
be used in the actual application.
THE NAILER MUST OPERATE PROPERLY.

ADJUSTING AIR PRESSURE

WARNING
Do not exceed 120 psi (8.3 bar 8.5 kgf/cm
Adjust the air pressure at recommended operating
pressure 70 – 120 psi (4.9 – 8.3 bar 5 – 8.5 kgf/cm
according to the length of nails and the hardness of
workpiece.
The correct air pressure is the lowest pressure which will
do the job. Using the Nailer at a higher than required air
pressure unnecessarily over stresses the Nailer.
Do not pull Trigger
2
).
2
)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nv 65acNv 50a1

Table des Matières