Pre-Installation - K2 Pumps WPS05002K Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING: This pump is designed for indoor installation only. Failure to install indoors will significantly increase the
risk of injury or death from electrical shock.

PRE-INSTALLATION

APPLICATION
This unit is a single stage jet pump designed for shallow well applications, where the water level is less than 25 ft.
deep. If the water level to the pump is deeper than 25 ft., a convertible jet pump or a deep well submersible pump
should be used. A pressure switch pre-set at 30 PSI "on", 50 PSI "off" has been installed on the pump. The pressure
switch will automatically turn the pump on and off based on the system pressure.
TOOLS REQUIRED
Flathead
Screwdriver
Safety goggles
WARNING: All joints and connections must be AIRTIGHT. A single leak will prevent the proper operation of the pump.
Wrap thread tape clockwise on all threaded connections. For all non-threaded connections, you must use PVC Purple
Primer and PVC Cement to ensure airtight seals. Measure all pipe lengths before attaching.
NOTE: A foot valve is a check valve that is used to keep the water from running back into the well from the pump and
maintain hydraulic pressure when the pump is not running. If the foot valve does not hold the water the pump will lose
it's prime and will not pump water. If the foot valve open pressure is too high (the spring is too stiff), or the flow area is
too small, the pump suction head and flow rate will significantly drop.
SPECIFICATIONS
Power supply
Liquid temp. range
Discharge size
Suction size
Water level
For Professional Technical Support call 1-844-242-2475
Phillips
Screwdriver
115V/230V, 60 HZ., 20/10Amp circuit
32° F to 95° F(0° - 35° C)
1 in. FNPT
1 in. FNPT
25 ft.
Wrench
Tape Measure
Thread Tape
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wps07502k