2. Well To Pump Connection
For Professional Technical Support call 1-844-242-2475
2. Install screen surround the foot valve, protect the foot valve
assembly from fish, trash, etc. Position the foot valve 5 feet
above bottom of well and
below the water level in order to prevent the pump from
sucking air.
(Fig 2)
3. Cement 1in. PVC MPT×S Male Adapter into 1 in. PVC
rigid Pipe. Install 1in.PVC TEE FPT×FPT×FPT to adapter.
One end of horizontal port install another 1in. PVC MPT×S
Male Adapter and 1in. PVC rigid Pipe. Add sections of pipes
to reach the 1in. PVC Slip ×Slip Union (optional). (Fig. 3)
1. Thread 1in. PVC MPT×S Male Adapter into pump.
Cement a short horizontal 1in. PVC rigid Pipe into adapter.
(Fig.1)
2. For pre-charged tank connection. Cement a 1in. PVC
Slip× Slip Union into a short horizontal 1in. PVC rigid Pipe.
Slopes all inlet piping slightly upward from well to the pump
to prevent trapping air.(Fig.2)
For standard tank connection. Cement 1in. ×1in. ×3/4in.
PVC S×S×FPT Reducer Tee Fitting into a short horizontal
1in. PVC rigid Pipe and cement another a short horizontal
1into the side of the tee fitting, then install3/4in.
MIP×1/2in.FIP Lead-Free Brass Hex Bushing Fitting to
the port of 3/4in, thread and another 1/2in. MIP×1/8in.FIP
Lead-Free Brass Hex Bushing Fitting to the bushing
fitting.
It should also be at least 10 feet
9