Overview

The Nupro Freedom® Cordless Prophy System with SmartMode® Technology offers a cordless design that eliminates
cord drag and allows clinicians easy access and comfort during prophylaxis procedures. SmartMode® Technology
controls the speed of the handpiece using the DPA's pressure against the tooth, eliminating the need for a foot pedal.
Quieter than the original Midwest
performance you would expect from a corded handpiece. The system includes a steam autoclavable outer sheath for
infection control.

1. Indications for Use

The Nupro Freedom® Cordless Prophy System with SmartMode® Technology is a high-performance cordless prophy
handpiece with an optional wireless foot pedal for use with Nupro Freedom
operatory to perform cleaning and polishing procedures on teeth.
2. Contraindications
None Known.
Safety Conventions in This Document
WARNING
PRECAUTION

3. Warnings

To prevent damage, charge the cordless handpiece using only the Nupro Freedom® with SmartMode® Technology
charging base for cordless handpiece and power supply and cord.
Sterilizing the cordless handpiece inner module will cause component damage to the cordless handpiece and the
sterilizing equipment, and may cause personal bodily injury.
The outer sheath must be steam sterilized before first use and between patients to prevent patient cross-
contamination. See Section 8 for the Infection Control Procedures.
The Disposable Prophy Angles are designed for single-patient use only and should never be used more than once.
Disposable Prophy Angles are not autoclavable or designed to withstand disinfection solutions. The risks of reuse
of a Disposable Prophy Angle are damage to equipment and patient cross-contamination. Install a new Disposable
Prophy Angle before each use.
It is the responsibility of the Healthcare Professional to determine the appropriate uses of this product and to understand:
• the health of each patient
• the dental procedures being undertaken
• applicable industry and governmental agency recommendations for infection control in dental healthcare settings
• requirements and regulations for safe practice of dentistry
• these Directions for Use in their entirety
Per FCC Part 15.21, changes or modifications not expressly approved by the party responsible for compliance (i.e., the
manufacturer) could void the user's authority to operate this equipment.
Failure to follow recommendations for environmental operating conditions (see Section 14 for Specifications) could
result in injury to patients or users.
Inspect the cordless handpiece system before each use for worn, loose or damaged parts. Do not attempt to operate
unless the Disposable Prophy Angle (DPA) is properly installed. A loose DPA could separate from the cordless
handpiece causing bodily injury. Reinstall the DPA or replace any damaged parts as necessary.
To prevent bodily injury and damage to the device, do not sterilize the Disposable Prophy Angle, cordless handpiece
inner module, charging base for cordless handpiece, optional wireless foot pedal or power supply and cord. Disinfect
the cordless handpiece inner module, charging base for cordless handpiece, optional wireless foot pedal or power
supply and cord using only the tested and approved disinfectants listed in Section 8, Infection Control Procedures.
The cordless handpiece inner module, optional wireless foot pedal, charging base for cordless handpiece and power
supply and cord are not waterproof. To prevent damage to the equipment, contamination or bodily injury, do not
immerse any of these components in water or a chemical solution.
Do not spray disinfectant or other fluids directly onto the cordless handpiece inner module, optional wireless
foot pedal, charging base for cordless handpiece, or power supply and cord to avoid liquid from pooling on the
component. The user should spray solution onto a cloth or use a wipe to disinfect these items per the instructions in
Section 8.
RDH
handpiece, the system offers all-day battery life while delivering the same
®
®
Use care to prevent personal and / or patient injury
Use care to prevent product damage and ensure safe and effective product use
®
Disposable Prophy Angles in a hygiene