When using the machine it is therefore compulsory for users to wear the
protection such as ear defenders or ear plugs to prevent damage to hearing
over time.

1.6.2. Vibration risk

The level of vibration was measured with the machines running as per UNI EN ISO
5349-1 2004 so as to evaluate the vibration transmitted to HAND-ARM.
The following results were obtained:
Level of hand-arm vibration: 17,3 m/s
Is recommended to use the tool in combination with appropriate PPE that attenuate
the actions.
PNEUMATIC FIXED POLES
APF 150 P
APF 200 P
APF 250 P
APF 300 P
APF 28 100 PE
APF 28 150 PE
APF 28 200 PE
APF 28 250 PE
APF 28 300 PE
PNEUMATIC TELESCOPIC POLES
APT 100 E CHIUSA
APT 100 E APERTA
APT 150 E CHIUSA
APT 150 E APERTA
APT 200 E CHIUSA
APT 200 E APERTA
20
OLIVANCE PN - PN S - PN T - PN X - PN XT
APF 50
Castellari S.r.l.
2
considering the most heavy use of the machine.
AVERAGE TIME OF USE (MINUTES)
Via Lasie 16/E
IMOLA (BO)
27
5
10
16
40
5
5
10
16
40
20
31
28
38
45
46
20