3. Specifications

3.5 Operating conditions

Operating conditions
Ingress protection (per IEC 60529)
EN
Vibration resistance
Shock resistance
Permissible temperature ranges
Rated temperature range
Ambient
Medium
Storage
3.6 Reference conditions (per IEC 61298-1)
Reference conditions (per IEC 61298-1)
Temperature
Atmospheric pressure
Air humidity
Power supply
Mounting position
3.7 Process connections
Standard
EN 837
DIN EN ISO 1179-2 (formerly DIN 3852-E)
10
IP67
The stated ingress protection only applies when plugged in using a mating connector that
has the appropriate ingress protection.
20 g (20 ... 2,000 Hz, 2 h) per IEC 60068-2-6
40 g (6 ms) per IEC 60068-2-27
-20 ... +70 °C [-4 ... +158 °F]
-20 ... +70 °C [-4 ... +158 °F]
-20 ... +70 °C [-4 ... +158 °F]
-25 ... +80 °C [-13 ... +176 °F]
15 ... 25 °C
860 ... 1,060 mbar (665 ... 800 mmHg)
45 ... 75 % relative, non-condensing
DC 24 V
DC 5 V with ratiometric output
as required
Thread size
G ⅛ B
G ¼ B
G ¼ A (Sealing ring from FKM)
WIKA operating instructions, model MG-1

Publicité

Table des Matières
loading