Phoenix Inverter
INVERTER
Input voltage range (V DC)
Output
(1)
Cont. output power at 25 °C (VA)
Cont. output power at 25 °C (W)
Cont. output power at 40 °C (W)
Peak power (W)
Maximum efficiency (%)
Zero-load power (W)
GENERAL
Programmable relay
Protection
(2)
Common Characteristics
ENCLOSURE
Common Characteristics
Battery-connection
230 V AC-connection
Weight (kg)
Dimensions (hxwxd)
STANDARDS
Safety
Emission / Immunity
1) Can be adjusted to 60Hz; 120V/60Hz on request
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non linear load, crest factor 3:1
4) Multipurpose relay which can be set for general alarm, DC undervoltage or genset start signal
function
20
Output voltage: 230 VAC ± 2%
(3)
(4)
Material & Colour: aluminium (blue RAL 5012) Protection: IP 21
Operating temp.: -20 to +50°C (fan assisted cooling)
Humidity (non condensing) : max 95%
M8 bolts (2 plus and 2 minus connections)
Screw clamp 13mm² (6 AWG)
444 x 328 x 240
EN 60335-1, EN 60335-2-29
EN55014-1, EN 61000-3-2 / EN 55014-2, EN 61000-3-3
24/5000
19 – 33
Frequency
:
5000
4500
4000
10000
94
25
Yes
a - g
30
48/5000
38 – 66
50 Hz ± 0,1%
5000
4500
4000
10000
95
25
Yes