Specified Conditions Of Use; Ec Declaration Of Conformity; Mains Connection - Milwaukee PD 705 Notice Originale

Masquer les pouces Voir aussi pour PD 705:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
Switch the device off immediately if the insertion tool stalls! Do
not switch the device on again while the insertion tool is stalled,
as doing so could trigger a sudden recoil with a high reactive force.
Determine why the insertion tool stalled and rectify this, paying
heed to the safety instructions.
Possible causes can be:
• it is tilted in the workpiece to be machined
• breakage of the material to be used
• the power tool is overloaded
Do not reach into the machine while it is running.
The insertion tool may become hot during use.
WARNING! Danger of burns
• when changing tools
• when setting the device down
Chips and splinters must not be removed while the machine is
running.
Always disconnect the plug from the socket before carrying out any
work on the machine.

SPECIFIED CONDITIONS OF USE

The percussion drill can be universally used for drilling and percussion
GB
drilling.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product described
under "Technical Data" fulfills all the relevant provisions of the
directives 2011/65/EU (RoHS), 2006/42/EC, 2014/30/EU
and the following harmonized standards have been used.
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 50581:2012
Winnenden, 2016-04-21
Alexander Krug / Managing Director
Authorized to compile the technical file
Techtronic Industries GmbH
Max-Eyth-Straße 10, 71364 Winnenden, Germany

MAINS CONNECTION

Appliances used at many different locations including wet room
and open air must be connected via a residual current device (FI,
RCD, PRCD) of 30mA or less.
Connect only to single-phase AC system voltage as indicated on
the rating plate. It is also possible to connect to sockets without an
earthing contact as the design conforms to safety class II.
Only plug-in when machine is switched off.
English
12
MAINTENANCE
The ventilation slots of the machine must be kept clear at all times.
If the machine is mainly used for percussion drilling, regularly
remove collected dust from the chuck. To remove the dust hold the
machine with the chuck facing down vertically, and completely open
and close the chuck. The collected dust will fall from the chuck. It is
recommended to regularly use cleaner for the clamping jaws and the
clamping jaw borings.
If the replacement of the supply cord is necessary, this has to be
done by the manufacturer or his agent in order to avoid a safety
hazard.
Use only Milwaukee accessories and Milwaukee spare parts. Should
components need to be replaced which have not been described,
please contact one of our Milwaukee service agents (see our list of
guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state
the Article No. as well as the machine type printed on the label
and order the drawing at your local service agents or directly at:
Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Winnen-
den, Germany.
SYMBOLS
CAUTION! WARNING! DANGER!
Always disconnect the plug from the socket before carrying
out any work on the machine.
Please read the instructions carefully before starting the
machine.
Accessory - Not included in standard equipment, available
as an accessory.
Do not dispose of electric tools together with household waste
material. Electric tools and electronic equipment that have
reached the end of their life must be collected separately and
returned to an environmentally compatible recycling facility.
Check with your local authority or retailer for recycling advice
and collection point.
Class II tool. Tool in which protection against electric shock
does not rely on basic insulation only, but in which additional
safety precautions, such as double insulation or reinforced
insulation, are provided. There being no provision for protec-
tive earthing or reliance upon installation conditions.
n
No-load speed
0
V
Volts
AC Current
European Conformity Mark
Ukraine Conformity Mark
EurAsian Conformity Mark

Publicité

Table des Matières
loading