Status display / Error codes

The symbols in the table below show the meter's operational status. The
status messages only appear in the main display (energy)! The temporary
display of the warning triangle can be caused by special operating states
and does not always mean that the device is malfunctioning. However,
should the symbol be displayed over a longer period of time, you should
contact the service company.
Symbol
Status
External voltage
Flow existent
Attention!
SSymbol flashing: Data transmission
Symbol constantly displayer: optical
interface active
Emergency operation
Code
Error
Temperature out of measuring range
1
Temperature out of measuring range
2
Short circuit return sensor
3
Interruption return sensor
4
Short circuit supply sensor
5
Interruption supply sensor
6
Battery voltage
7
Hardware error
8
Hardware error
9
Error in the measuring system
10
No water in the measuring tube
20
Reverse water flow detected
30
Air inside the medium
40
Measured value outside overload
50
range
Hardware error
100
Wireless interface
800
Status end of the battery
1000
Status Initial verification expired
2000
(**) only by zelsius
®
Error codes show faults detected by zelsius
error appears, the sum of the error codes is displayed: Error 1005 = error
1000 and error 5.
32
Français
C5-IUF
Measure
Check system /device
for errors
Exchange device
Measure
Check sensors
Check sensors
Check sensors
Check sensors
Check sensors
Check sensors
Exchange device
Exchange device
Exchange device
Exchange device (**)
Check operating pressure (**)
Check installation position (**)
Vent system (**)
Check dimensioning (**)
Exchange device
Exchange device
Exchange device respectively
battery
Exchange device
C5-ISF. If more than one
®
-
-
-
-