Honeywell FENZY AERIS Notice D'utilisation page 9

Masquer les pouces Voir aussi pour FENZY AERIS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 53
FREQUENCY OF MAINTENANCE AND INSPECTION OPERATIONS
All the apparatuses must undergo the following inspections.
COMPONENTS
Mask
Full SCBA
COMPONENTS
Mask
Demand valve
Pressure reducer
Compressed air
cylinder
Cylinder valve
X) Required
1) For frequently-used apparatus
2) After use in aggressive environments or extreme conditions
3) For reserve stocks
4) Not if the apparatus is hermetically packaged
Note: For more information about the composition of kits, see the spare parts price list or contact HONEYWELL.
Inspect the apparatus fully (working and sealing) after each change of spare parts.
Some parts have screws sealed using red varnish to certify that the parts were fitted at
HONEYWELL. The manufacturer is not liable for incorrect operation of any part that no longer
bears this seal.
Type of work required
Clean and disinfect
(See mask's instructions for use)
Cleaning
Test on bench
User function check
Type of work to be done by a
specialised maintenance
workshop
Replace:
- inhalation/exhalation valves
- seals
Replace:
- diaphragm
- spring
- valve
Replace:
- seal
- piston
Replacement of the high pressure
connector seal
Regular inspection and
requalification by an approved
body
Replace:
- seal
- closure member
Replace:
- Break seal
Before
After
use
use
X
X
X(2)
X
X
Every
Every
year
2 years
X
X
Refer to and follow the national regulations
applicable to compressed air reserves
Once every 5 years or more often
At least once every 12 months
EN-7
Every
Every
six
year
months
X(3)
X(4)
X(1)
X
Every
Every
6 years
10 years
X(3)
X (1)
X
X (1)
X

Publicité

Table des Matières
loading

Table des Matières