x2
***
0---
ALT
follow the user guide
add. start
Add. 2ch
erase 64
language
**
autoset
stat
vers
- +
n. cycles
- +
n. remotes
- +
err
0---
password
** Only active on LEO B CBB 3 230 L02
www.metalines.com
ACCESS MENUS Fig. 1
10--
150-
1520
hidden butt
release
hidden butt
release
Diagnostics
code
STRE
STRI
OPEN
CLS
PED
TIME
STOP
PHOT
PHOP
PHCL
BAR
BAR 2
SWC
SWO
SET
Control unit
ER01
software version
OK
bft . . .
ER02
+/-
No total
ER03
manoeuvres(in hundreds)
0000
OK
ER04
+/-
No radio control
ER05
devices memorised
OK
00
er06
+/-
List of last 30 errors
ER1x
*
01.33
OK
ER3x
*
02.01
ER5x
*
........
30.15
ER7x
*
+/-
10--
ok
See PARAMETERS MENU
See LOGIC MENU
desired button
desired button
See RADIO MENU
DESCRIPTION
START E external start input activated
START I internal start input activated
OPEN input activated
CLOSE input activated
PED pedestrian input activated
TIMER input activated
STOP input activated
PHOT photocell input activated
PHOT OP opening photocell input activated
PHOT CL closing photocell input activated
BAR safety edge input activated
BAR safety edge input activated on slave motor
(opposite leaves connection)
SWC motor closing limit switch input activated
SWO motor opening limit switch input activated
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
order to acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
Safety edge test failed
Opening photocell test failed
Closing photocell test failed
Safety edge test on slave motor failed (opposite leaves
connection)
8k2 safety edge test failed
Board hardware test error
Reverse due to obstacle - Amperostop
Communication error with remote devices
Internal system supervision control error.
*X= 0, 1, .., 9, A, B, C, D, E, F
150-
1520
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
35. 4 0
Obstacle threshold
Instantaneous force motor
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or param-
eter/logic setting
Check photocell connection and/or param-
eter/logic setting
Check safety edge connection and/or param-
eter/logic settings
Check safety edge connection and/or param-
eter/logic settings
-
C h e c k
c o n n e c t i o n s
- Hardware problems with board (contact
technical assistance)
Check for obstacles in path
Check connection with serial-connected
accessory devices and/or expansion boards
Try switching the board off and back on again.
If the problem persists, contact the technical