Complete Installation; Install Access Panel - Maytag MDB7959SKZ Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

COMPLETE INSTALLATION

46.
Reconnect float switch
Check that the power supply wire or cord does not touch
dishwasher motor or the lower part of the dishwasher tub.
Reconnect float switch by aligning connector removed in Step 10
with the connector housing and pushing in until the locking tab is
visible over the back of the connector.
47.
Replace drip tray
NOTE: Before replacing the dip tray, ensure that there is no water
present in the tray.
To replace drip tray, align with snaps in side members and push
in toward unit. It is important that the black hoses are above the
drip tray on both ends once it is pushed all of the way in.
26
48.
Power supply cord—Plug into
a grounded 3 prong outlet
Plug into a grounded 3 prong outlet.
49.
Reconnect power
Reconnect electrical power at the fuse box or circuit
breaker box.
NOTE: With the access panel off, start the dishwasher and allow it
to complete the shortest Installation
manual under Check Operations section.

INSTALL ACCESS PANEL

50.
Reinstall toe and access panel and
fasteners
Insulation
(on some models)
Place the toe panel behind the access panel against the
dishwasher leg. If insulation is included on this model, make sure
insulation does not interfere with the float assembly. Push the
access panel up toward the top of the product so that it hangs on
the hooks on the plastic side members.
Cycle. See instructions on this