TROUBLE SHOOTING
Problem
Motor will not start.
The motor stops directly
after starting.
Pump runs but no suction.
Pump runs but poor suction. Hole in the hose.
Machine blows dust.
Abnormal sound from
machine.
2010-02-17
Fault
Machine not connected.
Thermal overload tripped.
Incorrect fuse.
Thermal overload not set
correctly.
Hose not connected.
Hose plugged.
The container is not fi rmly
attached to the bottom
of the cyclone.
Pump rotation backwards.
Plugged fi lter.
Hose too long or too small.
Hose is kinked.
Machine top is mounted
incorrectly.
Dust is packed in the
cyclone.
Filter is perforated or has
come loose.
Particles in the pump.
DC 5800i 9.2 kW S - 11
Solution
Make sure connection.
Wait 5 minutes.
Change to
correct circuit.
Electrician should adjust.
Connect the hose.
Find and remove block.
Secure the container.
Electrician should change
phases.
Change or repair hose.
Clean or change fi lter.
Change the hose.
Check and free.
Adjust the mounting.
Take off the top and clean
out.
Check the fi lters and change
if necessary.
Order service.