Model Designation - Hatco HCWBI Serie Manuel D'installation Et D'utilisation

Cuves chauffantes/réfrigérantes prêtes à l'installation
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT SAFETY INFORMATION
NOTICE
Provide louvered or grill-style openings with a minimum
size of 12" x 12"/144 square inches (31 x 31 cm/
961 square cm) in the cabinetry in front of and behind the
condensing unit for proper ventilation. Failure to provide
adequate air flow through the condensing unit may cause
unit failure and will void the unit warranty.
Do not recirculate exhaust air inside cabinet when multiple
refrigerated wells are installed together. Intake air should
enter from outside of cabinet.
Transport and install unit in upright position only. Failure
to do so may result in damage to refrigeration system.
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
Auto-Fill units must be installed with adequate backflow
protection and must conform with all federal, state, and
local codes.
Do not use excessive force when tightening unions or
nuts. Over-tightening and excessive force may cause
leaks.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to unit.
Damage to any countertop material caused by heat or cold
generated from Hatco equipment is not covered under
the Hatco warranty. Contact manufacturer of countertop
material for application information.

MODEL DESIGNATION

Hot/Cold Well
H C W B I - x D A
Built-In
Insulated
Do not obstruct access to Hydro-Heater cleanout drains.
Make sure installation location allows access to cleanout
drains for daily cleaning.
Do not use steel wool for cleaning. Steel wool will scratch
the finish.
Clean unit daily to avoid malfunctions and maintain
sanitary operation.
Use non-abrasive cleaners and cloths only. Abrasive
cleaners and cloths could scratch finish of unit, marring its
appearance and making it susceptible to soil accumulation.
Do not use harsh chemicals such as bleach, cleaners
containing bleach, or oven cleaners to clean this unit.
Incoming water in excess of 3 grains of hardness per
gallon (GPG) (0.75 grains of hardness per liter [GPL])
must be treated and softened before being supplied to
water heater(s). Water containing over 3 GPG (0.75 GPL)
will decrease efficiency, increase energy use, and reduce
operating life of unit through increased lime build-up.
Product failure caused by liming or sediment buildup is
not covered under warranty.
Use only delimers that are non-corrosive to aluminum,
brass, and stainless steel. Damage to unit caused by
corrosive materials is not covered under warranty.
Inspect unit regularly for lime and sediment buildup.
Excessive buildup may affect performance and reduce
operating life of unit.
This unit is intended for commercial use only—NOT for
household use.
Auto-Fill Equipped
Drain Equipped
Full-Size Pan Capacity
4
English
NOTICE
Form No. HCWBIM-1017

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hcwbi-2daHcwbi-3daHcwbi-4daHcwbi-5daHcwbi-6da

Table des Matières