9. Specifications
Models PGT43.100, PGT43.160
Pressure limitation
Steady
Fluctuating
Overload safety
Temperature effect
Wetted materials
Process connection with lower
measuring flange
Pressure element
Sealing
Non-wetted materials
Case, bayonet ring
Movement
Dial
Pointer
Window
Ingress protection per IEC/EN 60529 IP54; option: IP65
For further specifications see data sheet PV 14.03
Model PGT43HP
Pressure limitation
Steady
Fluctuating
Overload safety
Temperature effect
Wetted materials
Process connection with lower
measuring flange
Pressure element
Sealing
Non-wetted materials
Case, bayonet ring
Movement
Dial
Pointer
Window
Ingress protection per IEC/EN 60529 IP54; option: IP65
For further specifications see data sheet PV 14.07
Pressure gauges with output signal, optionally for hazardous areas
Full scale value
0.9 x full scale value
5 x full scale value, however max. 40 bar
When the temperature of the measuring system deviates from
the reference temperature (+20 °C): max. ±0.8 %/10 K of full
scale value
Stainless steel 316L
≤ 0.25 bar: Stainless steel 316L
> 0.25 bar: NiCr alloy (Inconel)
FPM/FKM
Stainless steel
Brass
Aluminium, white, black lettering
Aluminium, black
Laminated safety glass
Full scale value
0.9 x full scale value
40, 100 or 400 bar
When the temperature of the measuring system deviates from
the reference temperature (+20 °C): max. ±0.8 %/10 K of full
scale value
Stainless steel 316L
≤ 0.25 bar: Stainless steel 316L
> 0.25 bar: NiCr alloy (Inconel)
FPM/FKM
Stainless steel
Brass
Aluminium, white, black lettering
Aluminium, black
Laminated safety glass