Dometic Waeco SinePower MSI2312T Instructions De Montage Et De Service page 45

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
SinePower
9.3
Connecting the 230 V power cable
➤ Connect the 230 Vw connection cable with safety plug (fig. 1 3, page 3)
to the 230 Vw input jack (fig. 5 6, page 4).
➤ Connect the safety plug to the 230 Vw mains.
9.4
Connecting the 230 V output cable
!
WARNING!
Before connecting the 230 Vw output cable, make sure the invert-
er is switched off at the main switch.
➤ Connect the 230 Vw connection cable with safety plug (fig. 1 2, page 3)
to the 230 Vw output jack (fig. 5 7, page 4).
9.5
Connect multiple appliances
The device is equipped at delivery with galvanic isolation. For the safe oper-
ation of multiple appliances, it is essential that a circuit breaker (residual cur-
rent circuit breaker) is built into the socket distribution circuit, see sample
circuit diagram in fig. 6, page 5.
Sample circuit diagram legend:
No. in
fig. 6,
Explanation
page 5
1
230 Vw power source
2
additional devices, e.g. battery charger, refrigerator
3
DC power source (battery)
4
Inverter
5
Set grounding bridge (At delivery: not set, shown by dotted
line)
6
Circuit breaker (residual current circuit breaker)
7
Socket distribution circuit for appliances
EN
Connecting the inverter
45

Publicité

Table des Matières
loading

Table des Matières