Use; Battery Check/Setting On A New Machine - Nilfisk SR 1000S B Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

USER MANUAL

USE

WARNING!
On some points of the machine there are some
adhesive plates indicating:
– DANGER
– WARNING
– CAUTION
– NOTE
While reading this Manual, the operator must pay particular
attention to these symbols.
Do not cover these plates for any reason and immediately
replace them if they are damaged.
BATTERY CHECK/SETTING ON A NEW
MACHINE
The machine requires two 12 V batteries or four 6 V batteries
connected according to the diagrams (20, Fig. U).
The machine can be supplied in one of the following modes:
a.
WET or GEL batteries already installed on the
machine
1. Open the machine hood (10, Fig. C) and engage the
hood support rod (3, Fig. U), then check that the
batteries are connected to the machine with the
connector (6, Fig. U).
2. Disengage the support rod and close the hood.
Check that the hood is properly closed (the machine
must be as shown in Fig. C).
3. Insert the key into the ignition switch (2, Fig. B) and
turn it to "II" position (without pressing the pedal (5,
Fig. C)), then release it. If the green warning light (5,
Fig. B) turns on, the batteries are ready to be used.
If the yellow (4, Fig. B) or red (3, Fig. B) warning light
turns on, it is necessary to charge the batteries (see
the relevant procedure in the Maintenance chapter).
8
b.
WET batteries installed on the machine but without
electrolyte
1. Open the machine hood (10, Fig. C) and engage the
hood support rod (3, Fig. U).
2. Remove all battery caps (5, Fig. U).
WARNING!
Pay attention when using sulphuric acid, as it
is corrosive. If it comes in contact with skin or
eyes, rinse thoroughly with water and consult
a physician.
Batteries have to be filled in a well-ventilated
area.
Wear protective gloves.
3. Fill the battery cells (or elements) with sulphuric acid
for batteries (density from 1.27 to 1.29 kg at 25°C) in
accordance with the instructions shown in the
Battery Manual. The correct quantity of sulphuric
acid is shown in the Battery Manual.
4. Let the batteries rest and fill in with sulphuric acid in
accordance with the instructions shown in the
Battery Manual.
5. Charge the batteries (see the procedure in the
Maintenance chapter).
c.
Without batteries
1. Buy appropriate batteries (See the Technical Data
chapter and the diagrams (20, Fig. U)). For the
battery choice and installation, apply to qualified
battery Retailers.
2. Install the batteries.
3. Set the machine and the battery charger (if
equipped) according to the type of batteries installed,
according to the procedure shown in the following
paragraph.