Installation Instructions – LDRT4B/LDRT6B/LDRT67B Commercial Recessed LED Retrofit
Reflector and LED Module
1.
Place end of flexible conduit through frame opening
in ceiling exposing upper portion of quick disconnect
(Figure 29).
2.
Remove LED engine from protective packaging.
3.
Remove trim assembly from protective packaging and
rotate side clips (3) outwards. (Figure 30).
4.
Insert LED engine on to trim assembly. Align post on
LED engine with slot on trim assembly (Figure 31).
5.
Rotate side clips (3) into place to securely attach trim
assembly to LED engine (Figure 32).
6.
Trim ring (optional) should be placed between the
ceiling and lower trim.
7 .
Properly align the connector as shown in (Figure 33).
Plug in the luminaire quick disconnect on the module.
8.
Ensure the connector is properly engaged. (Figure 34).
9.
Install LED engine and trim assembly by inserting
torsion springs into spring receivers located inside
retrofit ring assembly on two sides (Figure 35).
10. Press LED module and reflector assembly into retrofit
ring assembly until flush with ceiling (Figure 36).
11. Restore power after installation of fixture is completed.
Luminaire
Quick
Disconnect
LED Engine
Trim Assembly
Figure 29
Figure 30
5
Torsion
Springs
Side Clips
Installation Instructions – LDRT4B/LDRT6B/LDRT67B Commercial Recessed LED Retrofit
IB520015EN
Housing Compatibility
Minimum installation height required is 5-1/2 inch. Ensure
wiring, conduit and socket cup are moved to the side if
possible.
Figure 31
Figure 32